Transformers only work with AC — not DC. DC produces constant flux → no change → no induced emf. Step-up transformer increases VOLTAGE but DECREASES current (power is conserved). National Grid uses high voltage to REDUCE current → reduces I²R power losses in transmission cables.
Transformer: AC in primary → alternating flux in iron core → emf induced in secondary. Turns ratio: Vs/Vp = Ns/Np. Step-up: Ns > Np. Power conservation: Vp×Ip = Vs×Is. National Grid: step-up to ~400 kV for transmission (low current → less I²R loss), step-down for consumers. AC only — DC gives constant flux, no induction.
Match each transformer scenario to the correct calculation. — drag the symbols on the right to match the component names on the left.
A transformer has 200 primary turns and 800 secondary turns. Input voltage = 230 V. Find the output voltage.
Vs/Vp = Ns/Np
Vp = 230 V, Np = 200, Ns = 800
Vs = Vp × (Ns/Np) = 230 × (800/200) = 230 × 4
Vs = 920 V (step-up transformer)
HT only — use the turns ratio equation to calculate transformer voltages and turns. Apply power conservation to find current in transformer circuits. Explain why the National Grid uses high voltage transmission and calculate power losses at different voltages.
Transformers (HT only, physics only) — not in Combined Science.